Ion-selective electrodes in organic elemental and functional group analysis a review (1975 to 1978) : supplement 1 by W. Selig

Cover of: Ion-selective electrodes in organic elemental and functional group analysis | W. Selig

Published by Dept. of Energy, Livermore Laboratory, for sale by the National Technical Information Service] in Livermore, Calif, [Springfield, Va .

Written in English

Read online

Subjects:

  • Electrodes, Ion selective,
  • Chemistry, Organic,
  • Chemistry, Analytic

Edition Notes

Book details

StatementWalter Selig
SeriesUCRL ; 52393
ContributionsLawrence Livermore Laboratory
The Physical Object
Paginationiv, 57 p. :
Number of Pages57
ID Numbers
Open LibraryOL14884990M

Download Ion-selective electrodes in organic elemental and functional group analysis

The literature on the use of ion-selective electrodes in organic elemental and functional group analysis is surveyed in some detail. The survey is complete through Chemical Abstracts, Vol. Get this from a library. Ion-selective electrodes in organic elemental and functional group analysis: a review.

[W Selig; Lawrence Livermore Laboratory.]. Get this from a library. Ion-selective electrodes in organic elemental and functional group analysis: a review ( to ): supplement 1. [W Selig; Lawrence Livermore Laboratory.].

Download Organic-functional-group-analysis ebook PDF or Read Ion Selective Electrodes In Organic Elemental And Functional Group Analysis handicapped by the non-availability of a book that could uncover various aspects of qualitative and quantitative organic analysis.

This book. A simple, selective and accurate method has been described for the rapid micro and submicro determination of organic nitrates and nitramines. It is ba Cited by:   A simple micromethod is described for the determination of hydrazines using the copper ion-selective electrode.

The method is based on direct potentiometric titration of the Cited by: 6. Ion-selective electrodes in organic functional group analysis: Micro- and submicro-determination of thiocarbonyl and thiol groups using the silver/sulphide and iodide electrodes.

Vogel, A Text Book of Quantitative Inorganic Cited by: 8. Ion-selective electrodes based on liquid membranes immobilise an active species, an organic molecule (dissolved in a solvent), in the pores of an inert polymer.

The typical active species. Ion-selective electrodes are widely used for non-destructive, rapid, sensitive and precise determination of many ions in a great variety of media and therefore, provide a powerful analytic tool.

Since the appearance of the first edition of Professor Koryta's book Cited by: The successful modification of the tips of a cellular microgripper into ion selective electrodes capable of sensing calcium ions at concentrations as low as 8x M is : Richard A Durst.

Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life Cited by: ION SELECTIVE ELECTRODES IN ENVIRONMENTAL ANALYSIS.

2+, Mg. 2+, and Cl –. It is estimated that market for ion-sensor-based analysers was worth >3 billion USD in. Interested in ISE analysis.

There are various analytical measuring techniques to determine the concentrations of substances in unknown samples, e.g. photometry, titration or. Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration Book Edition: 1.

2) INTRODUCTION TO ION SELECTIVE ELECTRODES a) Applications. b) Advantages. 3) BASIC THEORY OF ISE MEASUREMENTS. a) The pH Electrode. b) Differences Between pH. ION-SELECTIVE ELECTRODES FOR SIMULTANEOUS REAL-TIME ANALYSIS OF SOIL MACRONUTRIENTS A Dissertation presented to the Faculty of the Graduate School.

Design of Ion-selective Electrodes Solid state electrodes:In this case, the ion selective part is a solid substance in direct contact with the solution to be measured. The main characteristic of a.

TYPES OF ION SELECTIVE ELECTRODES. Also see: ELIT Ion-Selective Electrodes and How ISEs Work. a) General Discussion. Ion selective electrodes come in various shapes and sizes.

Ion-selective electrode method. Potentiometric methods also play a significant role in pharmaceutical, biological, clinical and environmental analysis with the introduction of new ion-selective electrodes. It is still one of the most promising analytical tools capable of determining both inorganic Author: Ricardo Salgado, Manuela Simões.

The first section introduces the electrochemical nomenclature necessary for under­ standing the literature on ion-selective electrodes and discusses the general principles behind all. An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a transducer (or sensor) that converts the activity of a specific ion dissolved in a solution into an electrical.

Ion selective electrodes are well known in the art to measure ionic species such as potassium, lithium, sodium, and calcium. However, developing ion selective electrodes to. of operation and methods of analysis involving Ion Selective Electrodes.

Page Section 1 Ion selective measurement 4 Basic theory 4 Selectivity, interferences, activity 5 Types of electrode 6 Section 2 Methods of analysis 9 electrodes 7 Ion Selective Book File Size: KB.

Principle of ion-selective electrode (I.S.E.) An ideal I.S.E. consists of a thin membrane across which only the intended ion can be transported. The transport of ions from a high conc. to a. When are ion-selective electrodes used.

How ion-selective electrodes work. Selectivity, ionic strength. Type of ion-selective electrodes. Typical measuring range. /5(34). PRINCIPLE AND APPLICATIONS OF ION SELECTIVE ELECTRODES-AN OVERVIEW Vishal Arun Naik Organic Chemistry, Mahatma Phule Arts, Science & Commerce College, File Size: KB.

Annual Review of Materials Science Composite Electroceramics R. Newnham Annual Review of Materials Science On Material Structure and Human History Cyril Stanley Smith Annual Cited by:   Biomembrane electrodes: It is an ion selective electrode which is coated with an enzyme-containing acrylamide gel.

The gel and enzyme are held in place on the surface of the. Really-Flow™ Solid-State combination Ion-selective Electrodes. Weiss Really-Flow ™ combination Ion-selective electrodes have a free flowing junction and provide adjustable. We continue in this second volume the plan evident in the first; i.e., of presenting a number of well-rounded up-to-date reviews of important developments in the exciting field of ion-selective Brand: Springer US.

Burnett et al.: Use of ion-selective electrodes for blood-electrolyte analysis (a) Glass electrodes are ion-selective electrodes in which the sensing membrane is a thin piece of. Ion selective electrodes can be used as endpoint indicators or to perform direct measurements and incremental techniques.

Electrode measurements are simpler and faster than other. The chemical analyses performed using the fluoride ion-selective electrode showed that the mean amount + SD of fluoride uptake of teeth of group A was [+ or -] mg/l.

Diode laser. Transient techniques for ion-selective membrane studies, E Lindner et al. Status of the reference method for the determination of ionized Ca in serum, plasma and whole blood, A Book Edition: 1. Analysis by Electrodes Ion selective electrodes are a technology that gives direct measurement of cations and anions such as sodium and fluoride, and can also measure dissolved gases such.

brane-type ion-selective electrodes have become available commercially and show great promise as fast and efficient tools for in situ monitoring and laboratory analysis of municipal and.

The Working Group on Selective Electrodes has taken into account recent revisions of IUPAC recommendations on nomenclature and selectivity coefficient determinations for ion-selective Cited by: Ion-selective electrodes.

A little theory These are electrodes with a sensitive membrane, selective for a particular ion. When the selective electrode is immersed in the sample, a potential. Perform quick and accurate measurements by using high quality Thermo Scientific™ Orion™ Ion Specific Electrodes and reagents for ion specific measurement.

We offer a comprehensive. Ion-selective electrodes (ISE) are pH laboratory electrodes that determine the concentration of specific ions. Choose from cost-effective ion-selective electrodes and solutions to combination. Ion selective electrodes(ISE) • - Also known as indicator electrodes • - Respond directly to the analyte • - Used for direct potentiometric measurements • - Selectively binds and .This study developed a new type of all-solid-state ion-selective electrode based on a transducing layer of a network of single-walled carbon nanotubes.

The extraordinary capacity of carbon .Many organic, inorganic, chelating, intercalating, and composite materials were studied as electroactive materials for the preparation of ion-selective membrane electrodes. Furthermore, Cited by: 3.

35964 views Monday, October 26, 2020